This is a good waveform |
View larger image
Download this waveform file for use with PicoScope
Primary Induced Voltage Waveform Notes
The vertical lines within this trace measured using the ‘X’ cursor, can be seen at 200 volts, in fact it is know that this voltage does measure 250 volts but only a 10x adaptor for the oscilloscope was available at the time of taking this waveform. This is called the induced voltage and is produced by a process called magnetic inductance.
The principal is based around a magnetic field (or flux) being produced when the coil’s negative terminal earth circuit is completed by the amplifier. When the circuit is complete, a magnetic field is produced and builds up until the coil’s magnetic field is maximised. At the point of ignition, the coils earth circuit is removed and the magnetic field or flux collapses across the coil’s windings, which in turn induces a voltage of 150 - 350 volts.
The height of the induced voltage (sometimes referred to as the primary peak volts) will be determined by the following points:-
- The number of turns in the primary circuit.
- The strength of the magnetic flux, which is proportionate to the current in the primary circuit.
- The rate of collapse, which is determined by the speed of the switching of the earth path.
A lower than anticipated induced voltage will result in a low coil output. The High Tension (HT) output will be proportionate to the induced voltage.
Use the settings shown in the example waveform to pre-set the oscilloscope to measure the voltages.
汽車診斷 | 汽車診斷儀 | 汽車故障診斷儀 | 汽車測試儀 | 汽車分析儀 | 汽車診斷示波器 | 汽車電路測試儀 | 汽車電路分析儀 | 發動機分析儀 | 發動機綜合分析儀 | 發動機檢測中心 | 點火分析儀 | 點火測試儀 | 汽車傳感器測試儀 | CAN總線示波器 | LIN總線示波器 | 汽車故障記錄儀 | 汽車傳感器分析儀 | 汽車檢測儀 | 噴油嘴測試儀 | 點火線圈測試儀 | 蓄電池測試儀 | 發電機測試儀 | 起動機測試儀 | ABS傳感器測試儀 | ECU測試儀 | ECM測試儀 | 進氣真空/壓力測試儀 | 排氣壓力測試儀 | 汽車技術培訓 | 爆震傳感器測試儀 | 缺火測試儀 | 缺缸測試儀 | 線路測試儀 | 引出線 | 汽車數字示波器 | 真空傳感器 | 高壓感應測試頭 | 無分電器點火測試頭 | 獨立點火(COP)感應測試頭 | 漏電測試儀 | 氣缸相對壓縮測試 | 電腦測試儀 | 發動機控制器測試儀 | 泄漏測試儀 | 熒光檢漏 | 超聲波檢漏 | 汽車數字萬用表 | 電流鉗表 | 電流勾表 | 點火正時燈 |